⚡ Safety Notice: Always disconnect mains power and shut water tap before servicing.
E
ElectroFix Pro
AL01 / AL02 AEG Refrigerators

AEG Fridge Alarm AL01/AL02: Temperature Too High

AL01 warns that the fridge zone is too warm and AL02 that the freezer temperature is rising or already too high, with an audible alarm and a flashing symbol on the display.

15 estimated minutes Basic Difficulty (DIY)

Common symptoms:

  • Continuous or intermittent beeping
  • AL01 or AL02 shown on the display
  • Food feels less cold than usual

Probable causes:

Door not fully closed or left open too long 50%

Food or a container preventing the door from closing fully lets warm air in continuously.

Recent power outage or hot food added 30%

After a blackout or storing freshly cooked food, the internal temperature rises temporarily and triggers the alarm until it stabilizes.

Worn door gasket or faulty temperature sensor 20%

The rubber door seal has lost its elasticity and doesn't seal tightly, or the sensor persistently gives incorrect readings.

Safe Inspection Checklist (Check off when completed):

1. Check the door seal

Remove any container that might be blocking full closure and check the rubber gasket for tears or dirt buildup.

2. Silence the alarm and wait for it to stabilize

Press the alarm button to stop the beeping. If the cause was a power cut or hot food, the temperature should normalize within a few hours.

3. Test whether the door seals tightly

Place a banknote or piece of paper between the gasket and frame and close the door; if it slides out easily, the seal isn't gripping properly.

When to call a professional technician?

If the AL01/AL02 alarm persists with the door properly closed, no recent change in food load, and no power outages, the temperature sensor or door gasket likely needs replacing by a technician.