⚡ Safety Notice: Always disconnect mains power and shut water tap before servicing.
E
ElectroFix Pro
E2 Teka Washers

Teka Washer Error E2: No Water Intake

Triggers when the Teka washer fails to fill the drum with water within the expected time when the program starts.

15 estimated minutes Basic Difficulty (DIY)

Common symptoms:

  • The program does not advance and the drum stays empty
  • E2 code on display
  • Repeated beeps after starting

Probable causes:

Water tap closed or insufficient pressure 55%

The washer receives no water because the tap is closed or house pressure is too low.

Inlet filter clogged with limescale 30%

The mesh filter at the rear connection accumulates sediment and restricts flow to the valve.

Faulty inlet solenoid valve 15%

The valve does not respond to the board's electrical signal and stays closed even with the tap open.

Safe Inspection Checklist (Check off when completed):

1. Check the supply tap

Fully open the tap feeding the washer and confirm normal pressure by testing another nearby tap.

2. Clean the inlet filter

Close the tap, disconnect the hose from the rear of the washer, and clean the mesh filter under tap water.

3. Reconnect and test the fill

Reattach the hose firmly, open the tap, and start a short program to check whether water enters correctly.

When to call a professional technician?

If E2 persists after checking the tap, pressure, and filter, the inlet solenoid valve is faulty and needs technician replacement.